{"id":2412,"date":"2026-11-23T12:03:29","date_gmt":"2026-11-23T11:03:29","guid":{"rendered":"https:\/\/indra.it\/?p=2412"},"modified":"2026-11-23T17:32:49","modified_gmt":"2026-11-23T16:32:49","slug":"case-study-integral-dbb-valve-injection-quill-caustic-soda","status":"publish","type":"post","link":"https:\/\/indra.it\/en\/case-study-integral-dbb-valve-injection-quill-caustic-soda\/","title":{"rendered":"Case Study \u2013 Integral DBB Valve with Injection Quill for Caustic Soda"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><strong>An international chemical company was looking for a compact and safe solution for injecting caustic soda into a process line. Indra developed an integral valve that combines isolation, non-return protection, venting and injection in a single body.<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Challenge<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The customer needed to inject small quantities of caustic soda into the centre of the pipeline to promote its dispersion within the process flow. The solution also had to provide backflow protection and allow the injection point to be isolated and depressurised before maintenance.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"896\" height=\"1200\" src=\"https:\/\/indra.it\/wp-content\/uploads\/2026\/11\/Gemini_Generated_Image_5fhpga5fhpga5fhp1-1.jpg\" alt=\"\" class=\"wp-image-2410\" srcset=\"https:\/\/indra.it\/wp-content\/uploads\/2026\/11\/Gemini_Generated_Image_5fhpga5fhpga5fhp1-1.jpg 896w, https:\/\/indra.it\/wp-content\/uploads\/2026\/11\/Gemini_Generated_Image_5fhpga5fhpga5fhp1-1-768x1028.jpg 768w\" sizes=\"auto, (max-width: 896px) 100vw, 896px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">In conventional configurations, these functions are performed by separate components, resulting in a larger footprint and more connections, which in turn increase the number of potential leak points.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Solution<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Indra designed a <strong>single integral valve body<\/strong> combining four functions:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Double Block &amp; Bleed:<\/strong> two isolation ball valves and one bleed valve, enabling safe maintenance operations.<\/li>\n\n\n\n<li><strong>Integrated check valve:<\/strong> prevents process fluid from flowing back into the chemical dosing line.<\/li>\n\n\n\n<li><strong>Injection quill:<\/strong> delivers caustic soda to the centre of the pipeline and is verified in accordance with ASME PTC 19.3 TW.<\/li>\n\n\n\n<li><strong>Compatible materials and seals:<\/strong> selected to ensure reliable sealing performance in the presence of caustic soda.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">The valve is designed in accordance with <strong>ASME B16.34<\/strong> and is <strong>fire-safe in accordance with API 607<\/strong>.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Key Design Considerations<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The project highlights several critical aspects of designing a chemical injection system.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1000\" height=\"709\" src=\"https:\/\/indra.it\/wp-content\/uploads\/2026\/11\/00.VSF_.jpg\" alt=\"\" class=\"wp-image-2397\" srcset=\"https:\/\/indra.it\/wp-content\/uploads\/2026\/11\/00.VSF_.jpg 1000w, https:\/\/indra.it\/wp-content\/uploads\/2026\/11\/00.VSF_-767x544.jpg 767w\" sizes=\"auto, (max-width: 1000px) 100vw, 1000px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Injection position:<\/strong> delivering the chemical to the centre of the pipeline promotes dispersion within the flow and prevents localised concentrations near the pipe wall, which could cause corrosion and reduce dosing effectiveness.<\/li>\n\n\n\n<li><strong>Injection quill verification:<\/strong> vortex shedding can generate vibrations and lead to fatigue failure. For this reason, the injection quill is verified in accordance with ASME PTC 19.3 TW, with particular attention to high-velocity process lines.<\/li>\n\n\n\n<li><strong>Backflow protection:<\/strong> the integrated check valve, positioned upstream of the injection quill, prevents process fluid from flowing back into the dosing line when the pump stops.<\/li>\n\n\n\n<li><strong>Material compatibility:<\/strong> the selection of valve seats and O-rings must take into account both the injected chemical and the process fluid. Some elastomers that are resistant to hydrocarbons may deteriorate when exposed to strong alkalis.<\/li>\n\n\n\n<li><strong>Safety and maintenance:<\/strong> the DBB configuration allows the injection point to be isolated and depressurised before maintenance work begins.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Integrating these functions into a single body also reduces fittings, potential leak points, overall dimensions and weight on the pipe nozzle.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Results<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Fewer potential leak points:<\/strong> four integrated functions without intermediate fittings.<\/li>\n\n\n\n<li><strong>Safer maintenance:<\/strong> isolation and depressurisation performed directly through the valve assembly.<\/li>\n\n\n\n<li><strong>Simplified installation:<\/strong> a compact assembly mounted directly onto the process line flange.<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">A Solution for Multiple Applications<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">The same design architecture can be adapted to a wide range of industrial processes:<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>Oil &amp; Gas:<\/strong> corrosion inhibitors, scale and hydrate inhibitors (methanol and glycols), and biocides.<\/li>\n\n\n\n<li><strong>Refining and petrochemicals:<\/strong> neutralising amines and pH control agents.<\/li>\n\n\n\n<li><strong>Gas distribution networks:<\/strong> odorant injection.<\/li>\n\n\n\n<li><strong>Chemical processing and water treatment:<\/strong> pH adjustment using acids and alkalis, antifoaming agents and process additives.<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Indra customises the injection quill length and geometry, connections, pressure class and materials to meet each customer&#8217;s specific operating conditions.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A solution designed and manufactured by Indra at its facility in Magenta (Milan), Italy.<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>An international chemical company was looking for a compact and safe solution for injecting caustic soda into a process line. Indra developed an integral valve that combines isolation, non-return protection, venting and injection in a single body. The Challenge The customer needed to inject small quantities of caustic soda into the centre of the pipeline [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":2392,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[29],"tags":[],"class_list":["post-2412","post","type-post","status-publish","format-standard","has-post-thumbnail","category-oil-gas-case-studies"],"acf":[],"_links":{"self":[{"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/posts\/2412","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/comments?post=2412"}],"version-history":[{"count":5,"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/posts\/2412\/revisions"}],"predecessor-version":[{"id":2418,"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/posts\/2412\/revisions\/2418"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/media\/2392"}],"wp:attachment":[{"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/media?parent=2412"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/categories?post=2412"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/indra.it\/en\/wp-json\/wp\/v2\/tags?post=2412"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}