What is 2oo3 Voting Logic?

The 2oo3 (2-out-of-3) configuration is a redundant safety architecture where the system requires at least two out of three independent sensors to detect a hazardous condition before initiating a shutdown. This voting logic provides optimal balance between safety and availability.

Unlike single-sensor systems that can cause spurious trips or fail dangerously, the 2oo3 architecture tolerates a single sensor failure while maintaining full safety protection. If one sensor fails or provides a false reading, the system continues normal operation while alerting operators to the fault.

Key principle: Two independent confirmations are required for shutdown, eliminating false trips while ensuring that a single point failure cannot compromise safety.

✓ Optimal balance: maximum safety with minimal spurious trips

Technical Specifications

Voting Logic

2-out-of-3 (2oo3) redundant configuration

Voting Logic

Available Configurations

Connections

Threaded (ASME B1.20.1)
Flanged (ASME B16.5 / API 6A)

Connections

Flanged (ASME B16.5 / API 6A)

Bore Size

8 mm | 10 mm

Pressure Rating

6,000 PSI (420 bar) | 10,000 PSI (690 bar)

Seal Options

Standard: PTFE
Optional: Graphite

Material

Stainless Steel 316/316L, Duplex, Alloy 625, Alloy 825, Hastelloy, Titanium, 6Mo, Monel 400
All materials NACE MR0175/ISO 15156 compliant

Certification

SIL 4 - IEC 61508 certified (each assembly)

Sold as Complete Set

Unlike the 1oo1 arrangement, the 2oo3 configuration is supplied as a single integrated assembly housed within one enclosure, complete with manifold and specified accessories for simplified installation and maintenance.

Key Features

Fault Tolerance

Tolerates single sensor failure without compromising safety or requiring shutdown. System continues operation while alerting maintenance to the fault.

DBB (Double Block & Bleed)

Integrated double isolation with vent capability for safe sensor maintenance and calibration without system shutdown.

Spurious Trip Reduction

Eliminates false shutdowns from single sensor malfunctions, reducing operational downtime and production losses.

SIL 4 Certified

Meets the highest safety integrity level per IEC 61508, ensuring maximum protection in critical applications.

System Configuration

Complete Set Includes

Assembly A: 2003 manifold + enclosure + accessories
Assembly B: 2003 manifold + enclosure + accessories
Assembly C: 2003 manifold + enclosure + accessories

Note: Each assembly operates independently. External logic solver required to implement 2oo3 voting algorithm across the three channels.

Enclosure Options (per Assembly)

Standard Enclosure (IP66)

St.St. 316/316L construction
L1: 580mm W × 606mm D × 1310/705mm H
L3: 780mm W × 606mm D × 1310/705mm H
IP66 environmental protection

Custom Enclosure

Tailor-made dimensions
Internal insulation available
Custom painting
Multi-instrument configurations

ATEX-Certified Accessories (per Assembly)

Monitoring & Control

Proximity switches (Ex-ia/Ex-d)
Junction box (Ex-ia/Ex-e)
Cable glands (Ex-d/e)

Environmental Protection

Self-regulating heater (Ex-ia/Ex-d)
Low temperature alarm
In-line thermostat

2oo3 vs 1oo1: Choosing the Right Configuration
Feature2oo3 Configuration1oo1 (Set of 3)
ArchitectureSingle manifold, 3 sensors3 independent assemblies
Voting LogicIntegrated 2-out-of-3External logic controller required
FootprintCompact, single enclosureThree separate enclosures
InstallationSingle tapping piping pointTriple tapping piping points
Best ForSpace-constrained panelsGeographically distributed sensing
Redundancy LevelSensor-level redundancyFull system redundancy

Need complete system redundancy?

Explore our 1oo1 Triple Redundant configuration for applications requiring full isolation between voting channels.

Typical Applications

Offshore Platform HIPPS

Space-constrained topsides where panel footprint is critical

Subsea Wellhead Protection

Compact enclosures for underwater or seabed installations

Gas Compression Stations

Pipeline overpressure protection with high availability requirements

LNG Terminal Safety Systems

Critical shutdown systems requiring fault tolerance

Refinery Process Units

High-pressure vessel protection with minimal spurious trip tolerance

FPSO Production Systems

Integrated safety systems with limited installation space

Need a more compact solution?

Explore our 1oo1 Configuration for integrated voting logic in a single manifold assembly.

Real-World Reference Projects

Indra has supplied Interlocking Manifolds for 460+ projects worldwide, including:
NMGL Project (Abu Dhabi, UAE) 1001 PT Configuration with flushing system
Coral North FLNG (Mozambique) 1001 configuration with ball valves and voting logic 2003
Dalma Gas Project (Abu Dhabi) Specially designed for "HIPPS level" with equalizing manifold for on-site instrument calibration